These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Intramembranous charge movement in frog cut twitch fibers mounted in a double vaseline-gap chamber. Author: Hui CS, Chandler WK. Journal: J Gen Physiol; 1990 Aug; 96(2):257-97. PubMed ID: 2212983. Abstract: Intramembranous charge movement was measured in cut twitch fibers mounted in a double Vaseline-gap chamber with either a tetraethylammonium chloride (TEA.Cl) or a TEA2.SO4 solution (13-14 degrees C) in the central pool. Charge vs. voltage data were fitted by a single two-state Boltzmann distribution function. The average values of V (the voltage at which steady-state charge is equally distributed between the two Boltzmann states), k (the voltage dependence factor), and qmax/cm (the maximum charge divided by the linear capacitance, both per unit length of fiber) were V = -53.3 mV (SEM, 1.1 mV), k = 6.3 mV (SEM, 0.3 mV), qmax/cm = 18.0 nC/microF (SEM, 1.1 nC/microF) in the TEA.Cl solution; and V = -35.1 mV (SEM, 1.8 mV), k = 10.5 mV (SEM, 0.9 mV), qmax/cm = 36.3 nC/microF (SEM, 3.2 nC/microF) in the TEA2.SO4 solution. These values of k are smaller than those previously reported for cut twitch fibers and are as small as those reported for intact fibers. If a correction is made for the contributions of currents from under the Vaseline seals, V = -51.2 mV (SEM, 1.1 mV), k = 7.2 mV (SEM, 0.4 mV), qmax/cm = 22.9 nC/microF (SEM, 1.4 nC/microF) in the TEA.Cl solution; and V = -34.0 mV (SEM, 1.9 mV), k = 10.1 mV (SEM, 1.1 mV), qmax/cm = 38.8 nC/microF (SEM, 3.2 nC/microF) in the TEA2.SO4 solution. With this correction, however, the fit of the theoretical curve to the data is poor. A good fit with this correction can be obtained with a sum of two Boltzmann distribution functions. The first has average values V = -33.0 mV (SEM, 2.8 mV), k = 11.0 mV (SEM, 0.5 mV), qmax/cm = 10.6 nC/microF (SEM, 1.0 nC/microF) in the TEA.Cl solution; and V = -20.0 mV (SEM, 3.3 mV), k = 17.0 mV (SEM, 2.0 mV), qmax/cm = 36.4 nC/microF (SEM, 2.3 nC/microF) in the TEA2.SO4 solution. The second has average values V = -56.5 mV (SEM, 1.3 mV), k = 2.9 mV (SEM, 0.4 mV), qmax/cm = 13.2 nC/microF (SEM, 1.0 nC/microF) in the TEA.Cl solution; and V = -41.6 mV (SEM, 1.4 mV), k = 2.5 mV (SEM, 0.8 mV), qmax/cm = 11.8 nC/microF (SEM, 1.7 nC/microF) in the TEA2.SO4 solution. When a fiber is depolarized to near V of the second Boltzmann function, a slowly developing "hump" appears in the ON-segment of the current record.(ABSTRACT TRUNCATED AT 400 WORDS)[Abstract] [Full Text] [Related] [New Search]