These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: A novel assay for the detection of anti-human platelet antigen antibodies (HPA-1a) based on peptide aptamer technology. Author: Thibaut J, Mérieux Y, Rigal D, Gillet G. Journal: Haematologica; 2012 May; 97(5):696-704. PubMed ID: 22133781. Abstract: BACKGROUND: Neonatal alloimmune thrombocytopenia is mostly due to the presence of maternal antibodies against the fetal platelet antigen HPA-1a on the platelet integrin GPIIb-IIIa. Accurate detection of anti-HPA-1a antibodies in the mother is, therefore, critical. Current diagnostic assays rely on the availability of pools of human platelets that vary according to donors and blood centers. There is still no satisfactory standardization of these assays. DESIGN AND METHODS: Peptide aptamer was used to detect and identify HPA-1a-specific antibodies in human serum that do not require human platelets. A peptide aptamer library was screened using an anti-HPA-1a human monoclonal antibody as a bait to isolate an aptamer that mimics the human platelet antigen HPA-1a. RESULTS: This is the first report in platelet immunology of the use of a peptide aptamer for diagnostic purposes. This assay gives better results than the MAIPA currently in use, detecting around 90% of the expected alloantibodies. CONCLUSIONS: This assay could help define a standard for the quantitation of anti-HPA antibodies. This report also demonstrates that peptide aptamers can potentially detect a variety of biomarkers in body fluids; this is of particular interest for diagnostic purposes.[Abstract] [Full Text] [Related] [New Search]