These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Beyond the short-term: clinical outcome and valve performance 2 years after transcatheter aortic valve implantation in 227 patients. Author: Bleiziffer S, Mazzitelli D, Opitz A, Hettich I, Ruge H, Piazza N, Lange R. Journal: J Thorac Cardiovasc Surg; 2012 Feb; 143(2):310-7. PubMed ID: 22137802. Abstract: OBJECTIVE: Although the procedural feasibility of transcatheter aortic valve implantation has been shown by multiple groups, longer-term data are rare. We report on 2-year follow-up clinical and echocardiographic results after transcatheter aortic valve implantation in 227 patients. METHODS: Patients' mean age was 81 ± 7 years, 59% were female, mean European System for Cardiac Operative Risk Evaluation was 21% ± 14%, mean Society of Thoracic Surgeons score was 7% ± 5%, and access routes were transfemoral (n = 164), transapical (n = 54), axillary (n = 5), or transaortic (n = 4). A CoreValve (Medtronic Inc, Minneapolis, Minn) prosthesis was implanted in 174 patients, and a SAPIEN prosthesis (Edwards Lifesciences, Irvine, Calif) was implanted in 53 patients. Clinical and echocardiographic investigations were performed at 6 months, 1 year, and 2 years. RESULTS: Survival was 88.5% at 30 days, 75.9% at 6 months, 74.5% at 1 year, and 64.4% at 2 years. Patients improved significantly in New York Heart Association class after 6 months (from 3.2 ± 0.5 to 1.7 ± 0.7, P < .001) and up to 2 years (1.9 ± 0.7). Cumulative incidences of myocardial infarction, stroke, and life-threatening or major bleeding were 2.7%, 6.2%, and 16.2% at 2 years, respectively. The postprocedural mean transprosthetic gradient was 12 ± 4 mm Hg for all valves and did not change up to 2 years, and the effective orifice area was 1.5 ± 0.4 cm² with no change over 2 years of follow-up. Moderate or severe prosthetic regurgitation was present in 8% of patients at 2 years. In 6% of patients, the paravalvular or valvular regurgitation grade increased significantly over time. CONCLUSIONS: With excellent functional recovery of the patients, good systolic valve function, and overall low morbidity at 2 years, transcatheter aortic valve implantation may be considered the treatment of choice for aortic valve stenosis in elderly patients with an increased risk for surgery with a heart-lung machine.[Abstract] [Full Text] [Related] [New Search]