These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Promotion of osseointegration of anodized titanium implants with a 1α,25-dihydroxyvitamin D3 submicron particle coating. Author: Cho YJ, Heo SJ, Koak JY, Kim SK, Lee SJ, Lee JH. Journal: Int J Oral Maxillofac Implants; 2011; 26(6):1225-32. PubMed ID: 22167427. Abstract: PURPOSE: A biochemical approach to implant surface modification may offer an alternative to physicochemical and morphologic methods for obtaining desirable bone-implant interfaces. The objective of this study was to investigate the bone tissue response to anodized titanium implant surfaces coated with a poly(D,L-lactide-co-glycolide) (PLGA) solution mixed with 1α,25-diydroxyvitamin D3 (1α,25-(OH)2D3) via an electrospray technique. MATERIALS AND METHODS: Threaded implants were manufactured and anodized under 300 V at 660 Hz for 3 minutes (control group). Half of the implants were then coated with 0.15 mL of the PLGA/1α,25-(OH)2D3 solution (5 μg/implant) via electrospray (experimental group). Surface topography was evaluated using field-emission scanning electron microscopy and optical interferometry. Forty-eight implants (12 implants per group per healing period) were surgically placed in random sites in the tibiae of 12 New Zealand white rabbits. After 4 and 12 weeks of healing, undecalcified ground sections were subjected to histologic and histomorphometric analyses. RESULTS: At week 4, the mean bone-to-implant contact ratio (BIC%) over the entire length of the implant in the experimental group was 37.08% ± 10.18%, versus 28.01% ± 8.70% in the control group. The mean BIC% value in the first four consecutive threads of the experimental group was 48.64% ± 15.92%, compared to 36.11% ±13.49% in the control group (P < .05). At week 12, the mean overall BIC% values were 39.10% ± 7.68% in the experimental group and 29.53% ± 9.49% in the control group. The mean BIC% value in the first four consecutive threads of the experimental group was 51.80% ± 16.41%, versus 37.35% ± 11.77% in the control group (P < .05). CONCLUSION: The current study demonstrated that the PLGA/1α,25-(OH)2D3 solution coating resulted in submicron-sized particles, which may stimulate bone formation adjacent to the surface of implants inserted into bone.[Abstract] [Full Text] [Related] [New Search]