These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: [Study of a wire-to-plate positive pulsed corona discharge reactor by emission spectroscopy].
    Author: Wang SB, Luo ZY, Zhao L, Xuan JY, Jiang JP, Cen KF.
    Journal: Guang Pu Xue Yu Guang Pu Fen Xi; 2011 Nov; 31(11):2896-900. PubMed ID: 22242480.
    Abstract:
    In order to get extensive knowledge of wire-to-plate pulsed corona discharge reactor, the influences of different diameters of wire electrode, different wire-to-plate and wire-to-wire spacing on OH radical generation were experimentally investigated under atmospheric pressure based on emission spectrum, and the spatial distribution of OH radicals in the electric field was also discussed in detail The results showed that OH radicals decrease along the X-axis, and the activation radius is approximately 20 mm; showing a trend of first increase and then decrease along the Y-axis, with the activation radius being more than 30 mm. OH radical has small change as the diameter of wire electrode changes below 2 mm, with a sharp decline as the diameter continues to increase. OH radical emission intensity increases as wire-to-wire spacing increases and decrease as wire-to-plate spacing increases.
    [Abstract] [Full Text] [Related] [New Search]