These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Is FENO50 useful diagnostic tool in suspected asthma?
    Author: Schleich FN, Asandei R, Manise M, Sele J, Seidel L, Louis R.
    Journal: Int J Clin Pract; 2012 Feb; 66(2):158-65. PubMed ID: 22257040.
    Abstract:
    BACKGROUND: Asthma diagnosis is based on the presence of symptoms and the demonstration of airflow variability. Airway inflammation measured by fractional exhaled nitric oxide, measured at a flow rate of 50 ml/s (FE(NO50)) remains a controversial diagnostic tool. AIM: To assess the ability of FE(NO50) to identify bronchial hyperresponsiveness (BHR) to methacholine (provocative concentration of methacholine causing a 20% fall in FEV(1); PC20M ≤ 16 mg/ml) and to establish whether or not symptoms relate to FE(NO50) and PC20M in patients with no demonstrated reversibility to β(2) -agonist. METHODS: We conducted a prospective study on 174 steroid naive patients with respiratory symptoms, forced expiratory volume in 1 s (FEV(1) ) ≥ 70% predicted and no demonstrated reversibility to β(2) -agonist. Patients answered to a standardised symptom questionnaire and underwent FE(NO50) and methacholine challenge. Receiver-operating characteristic (ROC) curve and logistic regression analysis assessed the relationship between PC20M and FE(NO50) , taking into account covariates (smoking, atopy, age, gender and FEV(1)). RESULTS: A total of 82 patients had a PC20M ≤ 16 mg/ml and had significantly higher FE(NO50) (19 ppb vs. 15 ppb; p < 0.05). By constructing ROC curve, we found that FE(NO50) cut-off value of 34 ppb was able to identify not only BHR with high specificity (95%) and positive predictive value (88%) but low sensitivity (35%) and negative predictive value (62%). When combining all variables into the logistic model, FE(NO50) (p = 0.0011) and FEV(1) (p < 0.0001) were independent predictors of BHR whereas age, gender, smoking and atopy had no influence. The presence of diurnal and nocturnal wheezing was associated with raised FE(NO50) (p < 0.001 and p < 0.05, respectively). CONCLUSION: The value of FE(NO50) > 34 ppb has high predictive value of PC20M < 16 in patients with suspected asthma in whom bronchodilating test failed to demonstrate reversibility or was not indicated. However, FE(NO50) ≤ 34 ppb does not rule out BHR and should prompt the clinician to ask for a methacholine challenge.
    [Abstract] [Full Text] [Related] [New Search]