These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Very late coronary stent thrombosis of a newer-generation everolimus-eluting stent compared with early-generation drug-eluting stents: a prospective cohort study.
    Author: Räber L, Magro M, Stefanini GG, Kalesan B, van Domburg RT, Onuma Y, Wenaweser P, Daemen J, Meier B, Jüni P, Serruys PW, Windecker S.
    Journal: Circulation; 2012 Mar 06; 125(9):1110-21. PubMed ID: 22302840.
    Abstract:
    BACKGROUND: Early-generation drug-eluting stents releasing sirolimus (SES) or paclitaxel (PES) are associated with increased risk of very late stent thrombosis occurring >1 year after stent implantation. It is unknown whether the risk of very late stent thrombosis persists with newer-generation everolimus-eluting stents (EES). METHODS AND RESULTS: We assessed the risk of stent thrombosis in a cohort of 12 339 patients with unrestricted use of drug-eluting stents (3819 SES, 4308 PES, 4212 EES). Results are incidence rates per 100 person-years after inverse probability of treatment weighting to adjust for group differences. During follow-up of up to 4 years, the overall incidence rate of definite stent thrombosis was lower with EES (1.4 per 100 person-years) compared with SES (2.9; hazard ratio, 0.41; 95% confidence interval, 0.27-0.62; P<0.0001) and PES (4.4; hazard ratio, 0.33; 95% confidence interval, 0.23-0.48; P<0.0001). The incidence rate per 100 person-years of early (0-30 days), late (31 days-1 year), and very late stent thrombosis amounted to 0.6, 0.1, and 0.6 among EES-treated patients; 1.0, 0.3, and 1.6 among SES-treated patients; and 1.3, 0.7, and 2.4 among PES-treated patients. Differences in favor of EES were most pronounced beyond 1 year, with a hazard ratio of 0.33 (EES versus SES; P=0.006) and 0.34 (EES versus PES; P<0.0001). There was a lower risk of cardiac death or myocardial with EES compared with PES (hazard ratio, 0.65; 95% confidence interval, 0.56-0.75; P<0.0001), which was directly related to the lower risk of stent thrombosis-associated events (EES versus PES: hazard ratio, 0.36; 95% confidence interval, 0.23-0.57). CONCLUSION: Current treatment with EES is associated with a lower risk of very late stent thrombosis compared with early-generation drug-eluting stents.
    [Abstract] [Full Text] [Related] [New Search]