These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Hyoscine N-butylbromide does not improve polyp detection during colonoscopy: a double-blind, randomized, placebo-controlled, clinical trial.
    Author: de Brouwer EJ, Arbouw ME, van der Zwet WC, van Herwaarden MA, Ledeboer M, Jansman FG, ter Borg F.
    Journal: Gastrointest Endosc; 2012 Apr; 75(4):835-40. PubMed ID: 22317882.
    Abstract:
    BACKGROUND: Colonoscopy is used for the detection of neoplastic polyps, although a significant miss rate has been reported. Limited data suggest that the administration of the antispasmodic hyoscine N-butylbromide during colonoscopy improves polyp detection. OBJECTIVE: To investigate whether the use of 20 mg hyoscine N-butylbromide intravenously during colonoscopy improves polyp detection or removal. DESIGN: A prospective, double-blind, placebo-controlled, randomized, clinical trial. SETTING: Nonacademic teaching hospital. PATIENTS: This study involved 674 patients who were routinely referred and accepted for either diagnostic or screening colonoscopy. INTERVENTION: Intravenous injection of either 1 mL hyoscine N-butylbromide (n = 340) or 0.9% NaCl solution (n = 334) when withdrawal was started. MAIN OUTCOME MEASUREMENTS: Polyp detection rate (PDR), adenoma detection rate (ADR), and the advanced lesion detection rate (ALDR), 5% trimmed mean number of polyps, mean withdrawal time. RESULTS: The cecal intubation rate was 96%. The PDR, ADR, and ALDR were 56% versus 60%, 30% versus 31%, and 14% versus 14% in the hyoscine N-butylbromide and placebo groups, respectively (all P values > .25). The means of the total number of detected, removed, and harvested polyps per patient were 1.13 versus 1.21, 1.03 versus 1.06, and 0.89 versus 0.89 in the hyoscine N-butylbromide and placebo groups, respectively (all P values > .37). Mean withdrawal time was 561 versus 584 seconds in the hyoscine N-butylbromide and placebo groups, respectively (P = .34). Multivariate analysis demonstrated no effect of hyoscine N-butylbromide on the investigated parameters. LIMITATIONS: Only experienced colonoscopists participated in the study. CONCLUSION: We found no evidence to support the use of hyoscine N-butylbromide during withdrawal of the colonoscope to improve polyp detection or removal. ( CLINICAL TRIAL REGISTRATION NUMBER: ISRCTN25405865.).
    [Abstract] [Full Text] [Related] [New Search]