These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Oil refinery wastewater treatment using physicochemical, Fenton and Photo-Fenton oxidation processes. Author: Tony MA, Purcell PJ, Zhao Y. Journal: J Environ Sci Health A Tox Hazard Subst Environ Eng; 2012; 47(3):435-40. PubMed ID: 22320696. Abstract: The objective of this study was to investigate the application of advanced oxidation processes (AOPs) to the treatment of wastewaters contaminated with hydrocarbon oil. Three different oil-contaminated wastewaters were examined and compared: (i) a 'real' hydrocarbon wastewater collected from an oil refinery (Conoco-Phillips Whitegate refinery, County Cork, Ireland); (ii) a 'real' hydrocarbon wastewater collected from a car-wash facility located at a petroleum filling station; and (iii) a 'synthetic' hydrocarbon wastewater generated by emulsifying diesel oil and water. The AOPs investigated were Fe(2+)/H(2)O(2) (Fenton's reagent), Fe(2+)/H(2)O(2)/UV (Photo-Fenton's reagent) which may be used as an alternative to, or in conjunction with, conventional treatment techniques. Laboratory-scale batch and continuous-flow experiments were undertaken. The photo-Fenton parametric concentrations to maximize COD removal were optimized: pH = 3, H(2)O(2) = 400 mg/L, and Fe(2+) = 40 mg/L. In the case of the oil-refinery wastewater, photo-Fenton treatment achieved approximately 50% COD removal and, when preceded by physicochemical treatment, the percentage removal increased to approximately 75%.[Abstract] [Full Text] [Related] [New Search]