These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Midterm results after endovascular treatment of acute, complicated type B aortic dissection: the Talent Thoracic Registry.
    Author: Ehrlich MP, Rousseau H, Heijmen R, Piquet P, Beregi JP, Nienaber CA, Sodeck G, Fattori R.
    Journal: J Thorac Cardiovasc Surg; 2013 Jan; 145(1):159-65. PubMed ID: 22329980.
    Abstract:
    OBJECTIVE: To assess the efficacy and midterm results of endovascular treatment of acute complicated type B dissection. METHODS: From January 1998 to March 2004, 29 patients (7 women and 22 men) with acute complicated aortic type B dissection (mean age, 61 years; range, 22-78), defined as aortic rupture, malperfusion, intractable pain, or uncontrolled hypertension, underwent endovascular stent graft placement with the Medtronic Talent device. Five patients (17%) had undergone previous surgery on the ascending aorta and/or aortic valve. The mean aortic diameter at intervention was 48 ± 13 mm. Follow-up was 100% complete and averaged 53 ± 41 months. RESULTS: The technical feasibility and success with deployment proximal to the entry tear was 100%, requiring partial or total coverage of the left subclavian artery in only 1 patient (3%). Hospital mortality was 17% ± 7% (70% confidence limit) with 6 late deaths. The causes of hospital death included multiorgan failure in 2 patients, aortic rupture in 2, and retrograde dissection in 1 patient. Three patients (10%) who survived the procedure developed neurologic complications (2 strokes and 1 transient ischemic attack). One patient required early conversion to surgery because of retrograde type A dissection. Furthermore, 4 patients developed a type Ia endoleak. A postprocedural increase in the distal aortic diameter was observed in 3 patients. The actuarial survival at 1 and 5 years was 79% and 61%, respectively. Freedom from treatment failure at 1 and 5 years (including reintervention, aortic rupture, device-related complications, aortic-related death, or sudden, unexplained late death) was 82% and 77%, respectively. CONCLUSIONS: Endovascular stent graft placement in acute complicated type B aortic dissection proves to be a promising alternative therapeutic treatment modality in this relatively difficult patient cohort. Refinements, especially in stent design and application, could further improve the prognosis of patients in this life-threatening situation.
    [Abstract] [Full Text] [Related] [New Search]