These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Parameter estimations for the cerebrospinal fluid infusion test.
    Author: Eisenträger A, Sobey I, Czosnyka M.
    Journal: Math Med Biol; 2013 Jun; 30(2):157-74. PubMed ID: 22345141.
    Abstract:
    We consider parameter estimation for a single compartment model of a cerebrospinal fluid (CSF) infusion test using an inverse power law cerebral compliance depending on intracranial pressure (ICP). A least squares optimization is used to solve the inverse problem of estimating model parameter values from ICP observed during an infusion test. The optimization is applied to synthetic test data and to clinical ICP data from a number of infusion tests.We show that in tests that successfully reach a new plateau pressure, the resistance to CSF outflow and elastance can be reliably estimated using an automated least squares process. We find that a single infusion test does not provide enough resolution to distinguish between compliance models.
    [Abstract] [Full Text] [Related] [New Search]