These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Vagal cooling and positive end-expiratory pressure reduce systemic to pulmonary bronchial blood flow in dogs. Author: Lakshminarayan S, Agostoni PG, Kirk W. Journal: Respiration; 1990; 57(2):85-9. PubMed ID: 2236937. Abstract: Positive end-expiratory pressure (PEEP) reduces systemic to pulmonary bronchial blood flow [Qbr(s-p)] presumably because it increases bronchial vascular resistance. Since PEEP increases lung volume and thus could stimulate pulmonary stretch receptors, we investigated the hypothesis that the PEEP-related decrease in bronchial blood flow was due to a reflex mediated by the vagus. In open-chest dogs the left lower lobe (LLL) was isolated, independently ventilated, perfused in situ with a closed pulmonary vascular circuit and weighed continuously. Qbr(s-p) was measured as LLL vascular circuit overflow and changes in LLL weight. When LLL PEEP was increased from 5 to 15 cm H2O in a group of 11 dogs Qbr(s-p) was reduced by half from 60.8 +/- 10.5 to 31.6 +/- 6.1 ml/min/100 g dry lobe weight. In another group of 7 dogs Qbr(s-p) was 46.5 +/- 6.9 with PEEP = 5 cm H2O; it decreased to 28.3 +/- 6.8 with bilateral cervical vagal cooling (0-1.5 degrees C) and did not decrease further after increasing PEEP to 15 cm H2O. We conclude that the effect of resting vagal tone is to increase Qbr(s-p) and that the effect of PEEP on Qbr(s-p) may be mediated at least partially by vagal influences.[Abstract] [Full Text] [Related] [New Search]