These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Wavelet analysis demonstrates no abnormality in contralateral suppression of otoacoustic emissions in tinnitus patients.
    Author: Geven LI, Wit HP, de Kleine E, van Dijk P.
    Journal: Hear Res; 2012 Apr; 286(1-2):30-40. PubMed ID: 22387429.
    Abstract:
    The efferent auditory system is thought to play a role in the origin of tinnitus. Part of this system can be tested in humans with contralateral suppression of otoacoustic emissions. Stimulation of the medial olivocochlear efferent system is responsible for this reduction of otoacoustic emissions after contralateral acoustic stimulation. Previous research on patients with tinnitus showed inconclusive results. With wavelet analysis both time and frequency information of the emission can be analysed and compared. Contralateral suppression of otoacoustic emissions was therefore measured in tinnitus patients (n = 26) and normal subjects (n = 37) and analysed using wavelets. No significant difference in suppression was found between the tinnitus patients and the control group.
    [Abstract] [Full Text] [Related] [New Search]