These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Subcapital fracture of the femoral neck following internal fixation with a dynamic hip screw. Author: Blyme PJ, Iversen E, Burgaard P. Journal: Acta Orthop Belg; 1990; 56(2):517-9. PubMed ID: 2239201. Abstract: A case of subcapital femoral neck fracture following osteosynthesis of a trochanteric fracture is described. The implant used was the dynamic hip screw. This kind of fracture is very rare, and has to our knowledge never been described with the use of the dynamic hip screw.[Abstract] [Full Text] [Related] [New Search]