These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Corrosive tracheo-esophageal fistula following button battery ingestion. Author: Harjai MM, Ramalingam W, Chitkara G, Katiyar A. Journal: Indian Pediatr; 2012 Feb; 49(2):145-6. PubMed ID: 22410515. Abstract: We describe a case of corrosive tracheo-esophageal fistula following button battery ingestion in a 1-year old nonverbal pediatric patient. The delay in diagnosis was caused by failure to obtain correct history and failure to detect opacity of the battery in the neck at the first visit. The large fistula was successfully treated with division and repair with non absorbable sutures, with interposition of strap muscles between separated trachea and esophagus.[Abstract] [Full Text] [Related] [New Search]