These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Changes in baroreceptor sensitivity after eversion carotid endarterectomy. Author: Demirel S, Attigah N, Bruijnen H, Macek L, Hakimi M, Able T, Böckler D. Journal: J Vasc Surg; 2012 May; 55(5):1322-8. PubMed ID: 22459747. Abstract: OBJECTIVE: Posteversion carotid endarterectomy hypertension has been suggested to be associated with impaired baroreceptor sensitivity (BRS), which has been identified as a factor of prognostic relevance in patients with cardiovascular disease. The aim of this prospective single-center nonrandomized study was to describe the changes of BRS in the early postoperative period after eversion carotid endarterectomy (E-CEA). METHODS: Spontaneous BRS and hemodynamic parameters such as blood pressure (BP), heart rate (HR), cardiac output (CO), and total peripheral resistance (TPR) were evaluated preoperatively as well as postoperatively after 1 and 3 days using a noninvasive sequential cross-correlation method. Additionally, any modification in vasoactive medication due to BP derangement in the postoperative period was noted. Due to non-normal distribution of BRS, HR, and TPR samples, all measured values were expressed as medians with interquartile range (IQR), and a nonparametric test (Friedman) was performed. After adjustment for multiple testing, differences were considered statistically significant when the two-tailed P value was less than .0036. RESULTS: Thirty-five patients (mean age, 71 years) with symptomatic or asymptomatic internal carotid artery stenosis were included. The BRS significantly decreased to a lower level 24 hours after surgery (4.71 ms/mm Hg [3.02-6.1]) than preoperatively (5.95 ms/mm Hg [4.68-10.86]; P < .0001), resulting in a within-patient difference of -2.46 ms/mm Hg (95% confidence interval [CI], -8.38 - -1.52). This difference (95% CI, [- 1.58 (-8.24 - -0.80)]) persisted at the 72-hour measurements (5.63 ms/mm Hg [3.23-7.69]; P = .0005). The HR, reflecting the sympathetic activity, increased 24 hours after the operation (69 bpm [61.3-77.7]) compared with preoperative values (63 bpm [57.9-73.2]; P = .005) (within-patient difference [95% CI] 3.7 [1.5-8.5]), and this increase reached significance at 72 hours (69 bpm [65.4-77.5]; P = .001) (within-patient difference [95% CI] 5.5 [2.3-8.8]). Values of systolic pressure, diastolic pressure, mean arterial pressure, CO, and TPR were not significantly different between pre- and postoperative measurements. Overall, 23 (66%) patients developed significant postoperative hypertension requiring aggressive management with additional medications. CONCLUSIONS: E-CEA might have a decreasing influence on BRS, leading to increased sympathetic activity. Investigations of the longer-term effects of impaired BRS are warranted. These findings should be interpreted with caution, noting the limitation of an absent control group.[Abstract] [Full Text] [Related] [New Search]