These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Morphologic and functional evaluation before and after successful macular hole surgery using spectral-domain optical coherence tomography combined with microperimetry. Author: Chen WC, Wang Y, Li XX. Journal: Retina; 2012 Oct; 32(9):1733-42. PubMed ID: 22466479. Abstract: PURPOSE: To evaluate photoreceptor inner/outer segment (IS/OS) defects, best-corrected visual acuity (BCVA), macular sensitivity, and fixation stability to correlate morphologic changes with visual functional outcomes at different stages after macular hole surgery using spectral-domain optical coherence tomography combined with microperimetry. METHODS: This study was an interventional, retrospective case series. Sixteen eyes of 16 patients with successfully operated idiopathic full-thickness macular holes were included in this study. The IS/OS defect maximal diameter and area, BCVA, central macular sensitivity, mean macular sensitivity, and fixation stability were measured using spectral-domain optical coherence tomography combined with microperimetry, preoperatively, and with a follow-up of 3 months postoperatively. RESULTS: Both the IS/OS defect diameter and area improved after successful macular hole surgery (P < 0.001; P < 0.001). The BCVA, central macular sensitivity, mean macular sensitivity, and fixation stability of the central 2° also improved (P = 0.001; P = 0.004; P = 0.036; P = 0.031). Stable BCVA improvement was achieved as early as 1-month postoperation despite continuous repair of the IS/OS junction defect diameter and area and improvement in fixation and macular sensitivity within the first 3 months after surgery. The postoperative central macular sensitivity and mean macular sensitivity negatively correlated with preoperative linear IS/OS junction defect diameter (P = 0.033; P = 0.006) and the defect area (P < 0.001; P = 0.002). However, the postoperative BCVA and the improvement in BCVA, macular sensitivity, and fixation stability were not correlated with preoperative IS/OS defect diameter or area. CONCLUSION: Continuous anatomical and functional improvements can be observed after successful microinvasive macular hole surgery. The preoperative extent of the IS/OS junction defect is of good predictive value for postoperative macular sensitivity. However, the factors that influence BCVA are multiple. Prediction of BCVA based on a single anatomical parameter or assessment of macular function only based on BCVA should be avoided.[Abstract] [Full Text] [Related] [New Search]