These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Comparison of a DNA probe, complement-fixation and indirect immunofluorescence tests for diagnosing Anaplasma marginale in suspected carrier cattle. Author: Goff WL, Stiller D, Roeder RA, Johnson LW, Falk D, Gorham JR, McGuire TC. Journal: Vet Microbiol; 1990 Sep; 24(3-4):381-90. PubMed ID: 2260275. Abstract: Most estimates of the prevalence of anaplasmosis have been based on serologic data using the complement-fixation (CF) and/or card agglutination tests. Since these tests are considered to be only about 50 percent reliable for detecting carrier cattle in enzootically stable herds, the need for more sensitive diagnostic tests is widely recognized. The objective in the present study was to compare the sensitivity of the CF test with that of the indirect immunofluorescence (IIF) test and a recently developed DNA probe in determining the prevalence of Anaplasma marginale infection in cattle from an enzootic area. The study herd consisted of 52 8-month-old steers and 13 3-year-old cows of mixed beef breed. All cattle were initially tested for this comparative purpose. All but one animal (one that was a positive reactor as assessed by all three tests, and served as a positive control), were treated with long-acting oxytetracycline in an attempt to clear any carrier infections. Each animal was then retested at 1 month and 2 months post-treatment (PT), in an effort to determine if the DNA probe could be used to evaluate the effectiveness of the drug. Six of the 65 (9.2%) initial serum samples were CF positive. In contrast, 60 (92.3%) and 64 (98.5%) of the samples were positive as assessed with the IIF test and the DNA probe, respectively. The DNA hybridization reactions varied in intensity within the sample population indicating different individual levels of infection. The DNA probe hybridized with two samples taken at 1 month PT, and with two different samples taken at 2 months PT. The mean IIF titers were reduced at both the 1 month and 2 month sampling times. These results suggest that the drug did not eliminate infections in all cattle. Some may have been cleared, but, in any event, the drug did reduce the level of infections below the sensitivity of the DNA probe and interrupted continuity of stimulation of antibody. Therefore, the DNA probe and the IIF test appear to be considerably more sensitive in detecting carrier infections than the CF test, and should be considered in future epidemiologic studies.[Abstract] [Full Text] [Related] [New Search]