These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Biodegradation of BTEX in a fungal biofilter: influence of operational parameters, effect of shock-loads and substrate stratification. Author: Rene ER, Mohammad BT, Veiga MC, Kennes C. Journal: Bioresour Technol; 2012 Jul; 116():204-13. PubMed ID: 22609677. Abstract: The effect of relative humidity (RH: 30% to >95%) of a gas-phase mixture composed of benzene, toluene, ethylbenzene and para-, meta- and ortho-xylenes (BTEX), inlet concentrations (0.2-12.6 g m(-3)), and empty bed residence times (EBRTs) (48-144 s) was tested in a fungi-dominant biofilter. A maximum elimination capacity (EC(max)) of 244.2 gBTEX m(-3) h(-1) was achieved at a total inlet loading rate (ILR(T)) of 371.2 gBTEXm(-3) h(-1) (RH: 65%). The transient-state response was tested by increasing the ILR(T), in two steps, from ~50 to 850 gm(-3) h(-1) and from ~50 to 320 g m(-3) h(-1), at a constant EBRT of 41.7s. Increasing the ILR(T) reduced the total BTEX removal efficiency (RE(T)) from >97% to 35%, and from >90% to 60% during medium and high shock-load, respectively. When subjected to short (4d) and long-term (7d) shut-down periods, the biofilter was able to recover high EC(max) of, respectively, 200 and 72 gBTEX m(-)3 h(-1) after resuming operation.[Abstract] [Full Text] [Related] [New Search]