These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Electricity generation and microbial community in a submerged-exchangeable microbial fuel cell system for low-strength domestic wastewater treatment. Author: Yu J, Seon J, Park Y, Cho S, Lee T. Journal: Bioresour Technol; 2012 Aug; 117():172-9. PubMed ID: 22613893. Abstract: A submerged type microbial fuel cell (MFC) system, which consisted of six readily exchangeable air-cathode MFCs, was evaluated for continuous treatment of low-strength domestic wastewater. When supplied with synthetic wastewater (COD 100 mg/L), the system showed increasing maximum power densities from 191 to 754 mW/m2 as COD loading rates increased (0.20-0.40 kg/m3/day). COD removal efficiencies decreased with increased COD loading rates but the effluent COD concentrations met the relevant effluent quality standard (CODMn 20 mg/L) at all conditions. The system was then operated with domestic wastewater (c.a. 100 mg COD/L) at 0.32 and 0.43 kg/m3/day. The system showed much lower power densities (116-149 mW/m2) at both loading rates, compared to synthetic wastewater. Anodic microbial communities were completely different when the wastewater type was changed. These results suggest that the newly developed MFC system could be applied to treat low-strength domestic wastewater without requiring any additional organic removal stage.[Abstract] [Full Text] [Related] [New Search]