These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Contemporary incidence and predictors of stent thrombosis and other major adverse cardiac events in the year after XIENCE V implantation: results from the 8,061-patient XIENCE V United States study.
    Author: Naidu SS, Krucoff MW, Rutledge DR, Mao VW, Zhao W, Zheng Q, Wilburn O, Sudhir K, Simonton C, Hermiller JB.
    Journal: JACC Cardiovasc Interv; 2012 Jun; 5(6):626-35. PubMed ID: 22721657.
    Abstract:
    OBJECTIVES: The aim of this study was to identify predictors of clinical events after XIENCE V (Abbott Vascular, Santa Clara, California) stenting. BACKGROUND: The XIENCE V USA (XIENCE V Everolimus Eluting Coronary Stent System [EECSS] USA Post-Approval) study is a prospective, multicenter, Food and Drug Administration-required post-approval study to examine safety and effectiveness in real-world settings. After an initial 5,062 patients, 2,999 more were included as part of the DAPT (Dual Antiplatelet Therapy) trial (total n = 8,061). METHODS: One-year clinical events, including stent thrombosis (ST), cardiac death/myocardial infarction (MI), target lesion failure, and target lesion revascularization, were adjudicated according to Academic Research Consortium criteria, with ST and cardiac death/MI as primary and co-primary endpoints. Demographic, clinical, and procedural variables were assessed by multivariable analysis. A time-dependent covariate assessed the association between DAPT usage and ST. RESULTS: Roughly 61% were off-label; 85.6% remained on DAPT without interruption through 1 year. Incidences of definite/probable ST, cardiac death/MI, target lesion failure, and target lesion revascularization were 0.80% (95% confidence interval [CI]: 0.61% to 1.03%), 7.1% (95% CI: 6.51% to 7.68%), 8.9% (95% CI: 8.30% to 9.60%), and 4.3% (95% CI: 3.82% to 4.75%), respectively. Several independent clinical and angiographic predictors were identified for each outcome. Predictors of ST included DAPT interruption ≤ 30 days (hazard ratio [HR]: 8.63, 95% CI: 2.69 to 27.73, p = 0.0003), renal insufficiency (HR: 3.72, 95% CI: 1.71 to 8.09, p = 0.0009), and total stent length (HR: 1.30, 95% CI: 1.16 to 1.47, p < 0.0001). A DAPT interruption >30 days was not predictive of ST. CONCLUSIONS: In this large, real-world population, XIENCE V demonstrated low event rates at 1 year, with several independent predictors. Early DAPT interruption (≤ 30 days) was the most potent predictor of ST, whereas delayed interruption (>30 days) was not predictive. (XIENCE V Everolimus Eluting Coronary Stent System [EECSS] USA Post-Approval Study; NCT00676520).
    [Abstract] [Full Text] [Related] [New Search]