These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Cuff leak volume as a clinical predictor for identifying post-extubation stridor.
    Author: Keeratichananont W, Limthong T, Keeratichananont S.
    Journal: J Med Assoc Thai; 2012 Jun; 95(6):752-5. PubMed ID: 22774617.
    Abstract:
    BACKGROUND: Post-extubation stridor occurs after translaryngeal intubation results to re-intubation in a number of patients. OBJECTIVE: To determine the cut-off value of the cuff leak volume test among Thai patients as a predictor for post-extubation stridor MATERIAL AND METHOD: Demographic data and cuff leak volume were collected from patients who had been intubated with planned extubation. Clinical stridor was observed and identified after extubation. RESULTS: Among 115 patients, the cuff leak volume of less than 114 ml was used to predict post-extubation stridor with the sensitivity of 89%, specificity of 90%, positive predictive value of 65%, and negative predictive value of 98%, respectively. Among the stridor group, 12 of 19 cases (63.2%) needed re-intubation. CONCLUSION: The cuff leak volume of less than 114 ml can be used as a clinical predictor for identifying post-extubation stridor
    [Abstract] [Full Text] [Related] [New Search]