These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Determination of estradiol valerate in pharmaceutical preparations and human serum by flow injection chemiluminescence.
    Author: Liu W, Xie L, Liu H, Xu S, Hu B, Cao W.
    Journal: Luminescence; 2013; 28(3):407-11. PubMed ID: 22777916.
    Abstract:
    A novel method for the detection of trace estradiol valerate (EV) in pharmaceutical preparations and human serum was developed by inhibition of luminol chemiluminescence (CL) by estradiol valerate on the zinc deuteroporphyrin (ZnDP)-enhanced luminol-K3 Fe(CN)6 chemiluminescence system. Under optimized experimental conditions, CL intensity and concentration of estradiol valerate had a good linear relationship in the ranges of 8.0 × 10(-8) to 1.0 × 10(-5) g/mL. Detection limit (3σ) was estimated to be 3.5 × 10(-8) g/mL. The proposed method was applied successfully for the determination of estradiol valerate in pharmaceutical preparations and human serum and recoveries were 97.0-105.0% and 95.5-106.0%, respectively. The possible mechanism of the CL system is discussed.
    [Abstract] [Full Text] [Related] [New Search]