These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: [Determination of dimethyl ether in workplace air with gas chromatography]. Author: Meng CM, Zhang RQ, Qin WH. Journal: Zhonghua Lao Dong Wei Sheng Zhi Ye Bing Za Zhi; 2012 Feb; 30(2):142-3. PubMed ID: 22808552. Abstract: OBJECTIVE: To develop determination of dimethyl ether in workplace air by GC. METHODS: Dimethyl ether were sampled with solvent desorption active carbon tube. The sampled carbon tube were desorbed by carbon tetrachloride, Elite-WAX column was used with temperature programmed from 40 to 90 degrees C, and the carrier gas programmed from 1.4 - 2.5 ml/min. RESULTS: There was a good linearity (r = 0.9999) over the concentration of 0-63.91 microg/L, detection limit can reach 0.75 microg/ml. CONCLUSION: This method proved to be accurate and sensitive, to meet the determination of the dimethyl ether in workplace air.[Abstract] [Full Text] [Related] [New Search]