These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Renal sympathetic denervation using an irrigated radiofrequency ablation catheter for the management of drug-resistant hypertension.
    Author: Ahmed H, Neuzil P, Skoda J, Petru J, Sediva L, Schejbalova M, Reddy VY.
    Journal: JACC Cardiovasc Interv; 2012 Jul; 5(7):758-65. PubMed ID: 22814781.
    Abstract:
    OBJECTIVES: This study sought to assess whether renal sympathetic denervation (RSDN) can be achieved using an off-the-shelf saline-irrigated radiofrequency ablation (RFA) catheter typically employed for cardiac tissue ablation. BACKGROUND: RSDN using a specialized solid-tip RFA catheter has recently been demonstrated to safely reduce systemic blood pressure in patients with refractory hypertension. For cardiac tissue ablation, RFA technology has evolved from nonirrigated to saline-irrigated ablation electrodes to improve both safety and effectiveness. METHODS: Ten patients with resistant hypertension underwent renal angiography, followed by bilateral RSDN with a saline-irrigated RFA catheter. Ambulatory blood pressure recordings (24 h) were obtained at baseline, 1, 3, and 6 months after the procedure. Repeat renal angiography was performed during follow-up to assess for arterial stenosis or aneurysm. In 5 patients, pre- and post-procedural serum measures of renal function and sympathetic activity were obtained: aldosterone; metanephrine; normetanephrine; plasma renin activity; and creatinine. RESULTS: Over a 6-month period: 1) the systolic/diastolic blood pressure decreased by -21/-11 mm Hg; 2) all patients experienced a decrease in systolic blood pressure of at least 10 mm Hg (range 10 to 40 mm Hg); 3) there was no evidence of renal artery stenosis or aneurysm at repeat angiography; and 4) there was a significant decrease in metanephrine (-12 ± 4, p = 0.003), normetanephrine (-18 ± 4, p = 0.0008), and aldosterone levels (-60 ± 33 ng/l, p = 0.02) at 3 months. There was no significant change in plasma renin activity (-0.2 mg/l/hod, p = 0.4). There was no significant change in serum creatinine (-1 mmol/l, p = 0.4). CONCLUSIONS: These data provide the proof-of-principle that RSDN can be performed using an off-the-shelf saline-irrigated RFA catheter.
    [Abstract] [Full Text] [Related] [New Search]