Search MEDLINE/PubMed
Title: An Fe3O4-nanoparticles-based amperometric biosensor for creatine determination. Author: Kaçar C, Erden PE, Pekyardimci S, Kiliç E. Journal: Artif Cells Nanomed Biotechnol; 2013 Feb; 41(1):2-7. PubMed ID: 22889270. Abstract: An amperometric biosensor for the detection of creatine was designed, based on carbon paste electrode modified with Fe(3)O(4) nanoparticles. Electron transfer properties of unmodified and Fe(3)O(4)-nanoparticles-modified carbon paste electrodes were investigated by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) methods. Fe(3)O(4) nanoparticles increased the surface area and electric conductivity of the electrode, thus enhancing the sensitivity of the electrode. Optimum pH, buffer concentration, working potential and enzyme loading were selected as 7.0; 0.05 mol L(-1); +0.30 V and 2.0 Unit creatinase (CI), 1.0 Unit sarcosine oxidase (SO), respectively. The purposed biosensor exhibited linear response from 2.0 × 10(-7) mol L(-1) to 3.8 × 10(-6) mol L(-1) and from 9.0 × 10(-6) mol L(-1) to 1.2 × 10(-4) mol L(-1) with a detection limit of 2.0 × 10(-7) mol L(-1). Biosensor was used for determination of creatine in commercial creatine powder samples and showed a good sensing performance.[Abstract] [Full Text] [Related] [New Search]