These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Airborne indoor particles from schools are more toxic than outdoor particles. Author: Oeder S, Jörres RA, Weichenmeier I, Pusch G, Schober W, Pfab F, Behrendt H, Schierl R, Kronseder A, Nowak D, Dietrich S, Fernández-Caldas E, Lintelmann J, Zimmermann R, Lang R, Mages J, Fromme H, Buters JT. Journal: Am J Respir Cell Mol Biol; 2012 Nov; 47(5):575-82. PubMed ID: 22904196. Abstract: High concentrations of particulate matter (PM(10)) were measured in classrooms. This study addresses the hazard of indoor particles in comparison to the better-studied outdoor particles. Samples were taken from six schools during teaching hours. Genome-wide gene expression in human BEAS-2B lung epithelial cells was analyzed and verified by quantitative PCR. Polycyclic aromatic hydrocarbons, endotoxin, and cat allergen (Fel d 1) were analyzed by standard methods. Enhancement of allergic reactivity by PM(10) was confirmed in human primary basophils. Acceleration of human blood coagulation was determined with supernatants of PM(10)-exposed human peripheral blood monocytes. Indoor PM(10) induced serine protease inhibitor B2 (involved in blood coagulation) and inflammatory genes (such as CXCL6, CXCL1, IL6, IL8; all P < 0.001). Outdoor PM(10) induced xenobiotic metabolizing enzymes (cytochrome P450 [CYP] 1A1, CYP1B1, TIPARP; all P < 0.001). The induction of inflammatory genes by indoor PM(10) was explained by endotoxin (indoor 128.5 ± 42.2 EU/mg versus outdoor 13.4 ± 21.5 EU/mg; P < 0.001), the induction of CYP by outdoor polycyclic aromatic hydrocarbons (indoor 8.3 ± 4.9 ng/mg versus outdoor 16.7 ± 15.2 ng/mg; P < 0.01). The induction of serine protease inhibitor B2 was confirmed by a more rapid human blood coagulation (P < 0.05). Indoor PM(10) only affected allergic reactivity from human primary basophils from cat-allergic individuals. This was explained by varying Fel d 1 concentrations in indoor PM(10) (P < 0.001). Indoor PM(10), compared with outdoor PM(10), was six times higher and, on an equal weight basis, induced more inflammatory and allergenic reactions, and accelerated blood coagulation. Outdoor PM(10) had significantly lower effects, but induced detoxifying enzymes. Therefore, preliminary interventions for the reduction of classroom PM(10) seem reasonable, perhaps through intensified ventilation.[Abstract] [Full Text] [Related] [New Search]