These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Benefits of high-pitch 128-slice dual-source computed tomography for planning of transcatheter aortic valve implantation.
    Author: Plank F, Friedrich G, Bartel T, Mueller S, Bonaros N, Heinz A, Klauser A, Cartes-Zumelzu F, Grimm M, Feuchtner G.
    Journal: Ann Thorac Surg; 2012 Dec; 94(6):1961-6. PubMed ID: 22921235.
    Abstract:
    BACKGROUND: Transcatheter aortic valve implantation (TAVI) has emerged as an alternative treatment for high-risk and inoperable patients. Advanced multimodality imaging, including computed tomography (CT), plays a key role for optimized planning of TAVI. METHODS: Forty-nine patients (25 women; age, 82.3±8.8 year) with severe aortic stenosis scheduled for TAVI were examined with 128-slice high-pitch dual-source prospective aortoiliac CT angiography (CTA). The 3-coronary-sinus-alignment (3-CSA) plane, comprising left and right anterior oblique and craniocaudal projection, was defined from three-dimensional volume-rendered technique data sets and compared with the intraoperative angiographic plane (deployment plane) used for device implantation. A tolerance level of ±5-degree deviation was acceptable. Volume of intraoperative iodine contrast agent was compared before and after the implementation of the 3-CSA plane estimation by CT. RESULTS: All 49 patients underwent TAVI, during which 6 CoreValves (Medtronic, Minneapolis, MN) and 43 Sapien valves (Edwards Lifesciences, Irvine, CA) were successfully implanted using transapical (n=29), transfemoral (n=17), and transaxillary access (n=4). No severe complications occurred. In 47 patients (96%), CTA correctly predicted the 3-CSA plane used for device implantation. Mean left anterior oblique by CTA was 5.3±6.5 degrees and craniocaudal was -1.3±10.1 degrees. Mean left anterior oblique deviation between CTA and the intraoperative projection was 2.1±2.7 degrees and craniocaudal was 1.7±3.0 degrees. Ostium heights of the right and left coronary arteries were 12±1.9 and 12.9±3.3 mm. No over-stenting occurred in left coronary artery ostia of 8 mm or more. Contrast volume was reduced from 81.8±25.6 to 59.4±40.2 mL (p=0.05) when using 3-CSA plane estimation by CT for final prosthesis implantation plane. CONCLUSIONS: Aortoiliac high-pitch 128-slice dual-source CT contributes to TAVI planning, including reliable prediction of the 3-CSA valve deployment plane, which saves contrast volume during the procedure and may facilitate correct valve placement.
    [Abstract] [Full Text] [Related] [New Search]