Search MEDLINE/PubMed
Title: Measurement of radon/thoron exhalation rates and gamma-ray dose rate in granite areas in Japan. Author: Prasad G, Ishikawa T, Hosoda M, Sahoo SK, Kavasi N, Sorimachi A, Tokonami S, Uchida S. Journal: Radiat Prot Dosimetry; 2012 Nov; 152(1-3):130-4. PubMed ID: 22923241. Abstract: Radon and thoron exhalation rates and gamma-ray dose rate in different places in Hiroshima Prefecture were measured. Exhalation rates were measured using an accumulation chamber method. The radon exhalation rate was found to vary from 3 to 37 mBq m(-2) s(-1), while the thoron exhalation rate ranged from 40 to 3330 mBq m(-2) s(-1). The highest radon exhalation rate (37 mBq m(-2) s(-1)) and gamma-ray dose rate (92 nGy h(-1)) were found in the same city (Kure City). In Kure City, indoor radon and thoron concentrations were previously measured at nine selected houses using a radon-thoron discriminative detector (Raduet). The indoor radon concentrations varied from 16 to 78 Bq m(-3), which was higher than the average value in Japan (15.5 Bq m(-3)). The indoor thoron concentration ranged from ND (not detected: below a detection limit of approximately 10 Bq m(-3)) to 314 Bq m(-3). The results suggest that radon exhalation rate from the ground is an influential factor for indoor radon concentration.[Abstract] [Full Text] [Related] [New Search]