These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Fabrication of a fractured mandibular bar-retained implant overdenture without implant-level impression making: a clinical report. Author: Uludag B. Journal: J Prosthodont; 2012 Dec; 21(8):622-5. PubMed ID: 22938207. Abstract: The most frequent mechanical complications of bar-retained implant overdentures (IODs) are fracture of the dentures, loosening of the bar screws, and the need to reactivate the retentive clips. When a bar-retained IOD with an acrylic resin base fractures, the existing bar attachment should be removed to fabricate a new overdenture. So far, no method has been previously described for remaking a fractured mandibular bar-retained IOD without removing the existing bar attachment. This article describes fabrication of a fractured mandibular bar-retained IOD with distally placed ball attachments using attachment transfer analogs. The described technique allows the patient to use the existing overdenture temporarily until the new overdenture is delivered.[Abstract] [Full Text] [Related] [New Search]