These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Evaluation of high resolution gel β(2)-transferrin for detection of cerebrospinal fluid leak. Author: McCudden CR, Senior BA, Hainsworth S, Oliveira W, Silverman LM, Bruns DE, Hammett-Stabler CA. Journal: Clin Chem Lab Med; 2013 Feb; 51(2):311-5. PubMed ID: 23023885. Abstract: BACKGROUND: Cerebrospinal fluid (CSF) leaks are potentially life-threatening conditions that can be diagnosed by detection of β(2)-transferrin using protein electrophoresis. Another less commonly available test is β-trace protein quantitation using immunoassay. The objectives of this study were to evaluate a new immunofixation-based β(2)-transferrin test for detection of CSF leaks and to compare it to an existing agarose gel electrophoresis test and β-trace protein immunoassay. METHODS: For method comparison, 63 consecutive samples from physician-ordered β(2)-transferrin tests were analyzed using two different electrophoresis methods, agarose gel fractionation followed by acid-violet staining, and high resolution agarose gel electrophoresis followed by β(2)-transferrin immunofixation. A subset of samples (16/63) were analyzed for β-trace protein. Results were compared against patient chart data for the presence of a CSF leak. Additional studies were performed to assess the stability, detection limit, and analytical specificity of the β(2)-transferrin immunofixation test. RESULTS: The β(2)-transferrin immunofixation test had a sensitivity of 100 % (40/40) and specificity of 71 % (12/17) for detection of CSF leaks. By comparison, the agarose gel test had a sensitivity of 87 % (35/40) and specificity of 94 % (16/17). β-trace protein had a sensitivity of 100 % (10/10) and specificity of 86 % (5/6). Serum and saliva could be differentiated from CSF by the β(2)-transferrin immunofixation test based on their migration patterns. However, whole blood samples appeared positive for β(2)-transferrin at a threshold of ~ 4 g/L hemoglobin. At a cut-off of 3 mg/L, β-trace protein was increased in 10/10 cases with documented CSF leak and in 1/6 patients without CSF leak. CONCLUSIONS: Both the new immunofixation test for β(2)-transferrin and the β-trace protein were effective at detecting CSF leaks. Users of the β(2)-transferrin immunofixation test should be cautioned against interpreting samples with blood contamination.[Abstract] [Full Text] [Related] [New Search]