These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: [The significance of postoperative stability for osseous repair of a multiple fragment fracture. Animal experiment studies].
    Author: Heitemeyer U, Claes L, Hierholzer G.
    Journal: Unfallchirurg; 1990 Feb; 93(2):49-55. PubMed ID: 2315714.
    Abstract:
    The significance of postoperative mechanical stability for bony repair of a comminuted fracture was investigated in an animal experimental study comparing four commonly applied operative methods of stabilizing fractures: (1) flate osteosynthesis combined with lag screw fixation after reduction of the fragments; (2) bridging plate osteosynthesis; (3) external fixation; (4) static interlocking intramedullary nailing. As the fracture model, a triple-wedge osteotomy of the right sheep tibia was used. The results of in vitro testing of stiffness (N/mm) of each of the four osteosyntheses was as follows: anatomical plate: 746 N/mm; bridging plate 434 N/mm; external fixation 625 N/mm; nailing 416 N/mm. Eight weeks after the operation, the tibiae were explanted and the contralateral tibiae of six sheep were taken as a control group. The three-point bending test revealed no significant difference in bending deviation: anatomical plate 47.58 +/- 22.57 microns; bridging plate 33.93 +/- 7.67 microns; external fixation 33.83 +/- 8.02 microns; nailing 33.0 +/- 17.23 microns. However, it was noted that there was a slightly higher tendency towards stiffness of the bones after bridging plate osteosynthesis, external fixation and interlocking intramedullary nailing and that the amount of stiffness resembled that in non-operated control animals (25.56 +/- 6.66 microns). On the other hand, anatomical plate osteosynthesis showed less stiffness. To assess the tensile strength at the osteotomy area, bone samples were prepared and tested for failure on a material testing machine. The tensile strength of the bone samples showed a distinct difference in all experimental groups according to their anatomical location.(ABSTRACT TRUNCATED AT 250 WORDS)
    [Abstract] [Full Text] [Related] [New Search]