These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Correlation between endobutton loop length and tunnel widening after hamstring anterior cruciate ligament reconstruction.
    Author: Choi NH, Oh JS, Jung SH, Victoroff BN.
    Journal: Am J Sports Med; 2013 Jan; 41(1):101-6. PubMed ID: 23172006.
    Abstract:
    BACKGROUND: Previous reports have shown that graft fixation with the Endobutton is associated with tunnel widening because it provides distant fixation rather than aperture fixation. HYPOTHESIS: A longer loop of the Endobutton results in greater tunnel widening than a shorter loop. STUDY DESIGN: Cohort study; Level of evidence, 3. METHODS: A total of 171 consecutive patients underwent hamstring anterior cruciate ligament (ACL) reconstruction fixed with the Endobutton. They were followed for a minimum of 2 years postoperatively. A 15-mm loop was used in 20 patients, a 20-mm loop in 53, a 25-mm loop in 58, and a >30-mm loop in 40. On anterior-posterior (AP) and lateral radiographs, the measured diameters of the femoral tunnel at 2 years after surgery were compared with the diameter of the reamer used at surgery. The measured diameter of the tibial tunnel at 2 years after surgery was compared with measurements taken on the immediate postoperative day. The center of the tibial tunnel and direction of the ACL graft were also measured. Postoperative knee stability was evaluated using the Lachman test, pivot-shift test, and KT-1000 arthrometer. Functional evaluations were performed using the Lysholm score and Tegner activity scale. All measurements were compared among the 4 groups according to the length of the Endobutton loop. RESULTS: The mean ± standard deviation (SD) diameter of the femoral tunnel increased by 50.7% ± 23.3% and 37.0% ± 18.8% on AP and lateral radiographs at 2 years after surgery, respectively. The mean ± SD diameter of the tibial tunnel increased by 40.8% ± 19.3% and 46.4% ± 22.6% on AP and lateral radiographs, respectively. No significant difference in tunnel widening was present according to the length of the Endobutton loop. There were no significant differences in the average center of the tibial tunnel or the average angle of the direction of the ACL graft among the 4 groups. There was no significant difference in Lachman test results, postoperative KT-1000 arthrometer side-to-side differences, Lysholm score, and Tegner activity scale score among the 4 groups. The group with a >30-mm loop showed a significant difference in the pivot-shift test than the other 3 groups (P = .023). CONCLUSION: A longer Endobutton loop did not result in greater tunnel widening than a shorter loop. Long fixation distance may not be associated with tunnel widening after hamstring ACL reconstructions.
    [Abstract] [Full Text] [Related] [New Search]