  • Title: Fracture resistance of crowns cemented on titanium and zirconia implant abutments: a comparison of monolithic versus manually veneered all-ceramic systems.
    Author: Martínez-Rus F, Ferreiroa A, Özcan M, Bartolomé JF, Pradíes G.
    Journal: Int J Oral Maxillofac Implants; 2012; 27(6):1448-55. PubMed ID: 23189296.
    Abstract:
    PURPOSE: To evaluate the fracture resistance of all-ceramic crowns cemented on titanium and zirconia implant abutments. MATERIAL AND METHODS: Customized implant abutments for maxillary right central incisors made of titanium (Ti) and zirconia (Zr) (n=60, n=30 per group) were fabricated for an internal connection implant system. All-ceramic crowns were fabricated for their corresponding implant abutments using the following systems (n=10 per group): (1) monolithic computer-aided design/computer-assisted manufacture (CAD/CAM) lithium disilicate (MLD); (2) pressed lithium disilicate (PLD); (3) yttrium stabilized tetragonal zirconia polycrystal (YTZP). The frameworks of both PLD and YTZP systems were manually veneered with a fluorapatite-based ceramic. The crowns were adhesively cemented to their implant abutments and loaded to fracture in a universal testing machine (0.5 mm/minute). Data were analyzed using two-way analysis of variance (ANOVA) and Tukey's test (α=0.05). RESULTS: Both the abutment material (P=.0001) and the ceramic crown system (P=.028) significantly affected the results. Interaction terms were not significant (P=.598). Ti-MLD (558.5±35 N) showed the highest mean fracture resistance among all abutment-crown combinations (340.3±62-495.9±53 N) (P<.05). Both MLD and veneered ceramic systems in combination with Ti abutments (558.5±35-495.9±53 N) presented significantly higher values than with Zr abutments (392.9±55-340.3±62 N) (P<.05). MLD crown system showed significantly higher mean fracture resistance compared to manually veneered ones on both Ti and Zr abutments (P<.05). While Ti-MLD and Ti-PLD abutment-crown combinations failed only in the crowns without abutment fractures, Zr-YTZP combination failed exclusively in the abutment without crown fracture. Zr-MLD and Zr-PLD failed predominantly in both the abutment and the crown. Ti-YTZP showed only implant neck distortion. CONCLUSIONS: The highest fracture resistance was obtained with titanium abutments restored with MLD crowns, but the failure type was more favorable with Ti-YTZP combination.
    [Abstract] [Full Text] [Related] [New Search]