These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Concurrent antegrade transseptal Inoue-balloon mitral and aortic valvuloplasty.
    Author: Abdou SM, Chen YL, Wu CJ, Lau KW, Hung JS.
    Journal: Catheter Cardiovasc Interv; 2013 Nov 01; 82(5):E712-7. PubMed ID: 23197310.
    Abstract:
    BACKGROUND: The Inoue balloon has been in use for many years for mitral valvuloplasty. Aortic valvuloplasty using the Inoue balloon via transseptal approach was developed in the hope of providing better results with less potential vascular access complications. METHODS AND RESULTS: In this study, we present our experience in percutaneous valvuloplasty using the Inoue balloon in 14 patients with combined rheumatic mitral and aortic stenosis (AS) in a single stage procedure via antegrade transseptal approach. The study group was characterized by relatively young age (mean 37.5 ± 9.6 years). Aortic followed by mitral valvuloplasty via antegrade approach resulted in a fall of transaortic peak pressure gradient (PG) from 59.1 ± 11.2 mm Hg to 25.3 ± 12.5 mm Hg (P = 0.012) and mean from 49.0 ± 10.9 mm Hg to 16.6 ± 9.8 mm Hg (P = 0.043). Aortic valve areas increased significantly from 0.70 ± 0.25 cm(2) to 1.41 ± 0.48 cm(2) (P = 0.042). Mean transmitral PG decreased from 14.9 ± 2.1 mm Hg to 5.3 ± 1.5 with increase of mitral valve areas from 1.08 ± 0.45 to 1.92 ± 0.51 cm(2). The procedures were well tolerated without development of significant valvular regurgitation or thromboembolism. During follow-up, 2 patients died due to lung cancer and sudden death at months 48 and 100. Five patients received delayed surgery after mean duration of 73.4 ± 39.7 months. CONCLUSIONS: Concurrent antegrade, transseptal Inoue-balloon aortic and mitral valvuloplasty, is feasible and safe, and provides excellent immediate results as one-stage procedure. The study results also suggest that balloon aortic valvuloplasty can be more durable in younger patients with rheumatic AS than in elderly patients with degenerative, AS. However, the modified aortic valvuloplasty technique can be utilized only as bridging procedure to aortic valve replacement or recently developed transcatheter aortic-valve implantation in unstable hemodynamic status, and as a palliative procedure before noncardiac surgery.
    [Abstract] [Full Text] [Related] [New Search]