  • Title: Determination of sulfite in foods and beverages by ion exclusion chromatography with electrochemical detection: collaborative study.
    Author: Kim HJ.
    Journal: J Assoc Off Anal Chem; 1990; 73(2):216-22. PubMed ID: 2324032.
    Abstract:
    A liquid chromatographic (LC) method for determination of total sulfite in foods and beverages by alkali extraction followed by ion exclusion chromatographic separation and electrochemical detection (IEC-EC) was collaboratively studied by 9 laboratories. Blind duplicate samples of starch, diluted lemon juice, wine cooler, dehydrated seafood, and instant mashed potatoes were analyzed without spiking and with added sulfite at 2 levels. The initial sulfite levels varied from 0 to 384 ppm SO2, and the levels added varied from 10 to 400 ppm. The initial sulfite levels determined by the IEC-EC method and the Monier-Williams method were in good agreement. Recovery of added sulfite by the IEC-EC method was generally higher than that by the Monier-Williams method. Within-laboratory repeatability (RSDr) for the IEC-EC method varied from 4.4 to 26.0%, and overall reproducibility (RSDR) varied from 8.5 to 39.3%. The collaborators found the method to be fast, sensitive, and easy to use, which makes it a useful alternative to the Monier-Williams method. The method has been adopted official first action.