These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Determination of sulfite in foods and beverages by ion exclusion chromatography with electrochemical detection: collaborative study. Author: Kim HJ. Journal: J Assoc Off Anal Chem; 1990; 73(2):216-22. PubMed ID: 2324032. Abstract: A liquid chromatographic (LC) method for determination of total sulfite in foods and beverages by alkali extraction followed by ion exclusion chromatographic separation and electrochemical detection (IEC-EC) was collaboratively studied by 9 laboratories. Blind duplicate samples of starch, diluted lemon juice, wine cooler, dehydrated seafood, and instant mashed potatoes were analyzed without spiking and with added sulfite at 2 levels. The initial sulfite levels varied from 0 to 384 ppm SO2, and the levels added varied from 10 to 400 ppm. The initial sulfite levels determined by the IEC-EC method and the Monier-Williams method were in good agreement. Recovery of added sulfite by the IEC-EC method was generally higher than that by the Monier-Williams method. Within-laboratory repeatability (RSDr) for the IEC-EC method varied from 4.4 to 26.0%, and overall reproducibility (RSDR) varied from 8.5 to 39.3%. The collaborators found the method to be fast, sensitive, and easy to use, which makes it a useful alternative to the Monier-Williams method. The method has been adopted official first action.[Abstract] [Full Text] [Related] [New Search]