These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Comparative evaluation of the regional micro-push-out bond strength of custom-made resin post system with a prefabricated resin post: an in vitro study.
    Author: Ranjithkumar S, Velmurugan N, Roy A, Hemamalathi S.
    Journal: Indian J Dent Res; 2012; 23(4):484-9. PubMed ID: 23257482.
    Abstract:
    AIM: The purpose of the study is to compare the regional micro-push-out bond strength of custom-made resin post and a prefabricated resin post luted using self-etch adhesive and/or etch and rinse adhesive system at various regions. MATERIALS AND METHODS: Forty freshly extracted human maxillary central incisors were selected for this study; 1.5-2-mm coronal to the cemento-enamel junction was removed with a diamond disk using a slow speed handpiece under cooling water. Working lengths were established, root canals were sequentially enlarged upto the apex until ISO size 50-K-file and obturated using gutta-percha and AH plus sealer by cold lateral compaction. Post spaces were prepared to a depth of 10 mm using paeso-reamer upto size #3. After preparation, each specimen was embedded in chemically cured acrylic resin. The roots were randomly assigned to four groups: Group I: Custom-made resin post+Self-etch adhesive, Group II: Glass FRC post+Self-etch adhesive, Group III: Custom-made resin post+Etch and Rinse adhesive, Group IV: Glass FRC post+Etch and Rinse adhesive. Fabrication of custom-made resin post was done. All the posts were cemented using a dual cure resin luting cement. Each root was sectioned perpendicular to the long axis using a microtome and subjected to micro-push-out bond strength. RESULTS: The micro-push-out bond strength in the coronal region, in Group I 13.5 ± 1.66 MPa, Group II 12.08 ± 0.8 MPa, Group III 11.15 ± 1.06 MPa, Group IV 11.81 ± 1.11 MPa. In the middle third region: Group I 11.43 ± 0.740 MPa, Group II 10.584 ± 0.504 MPa, Group III 10.0582 ± 0.830 MPa, Group IV 10.35 ± 0772 MPa. In the apical third: Group I 10.38 ± 0.878 MPa, Group II 9.59 ± 1.06 MPa, Group III 9.34 ± 0.73o MPa, Group IV 8.77 ± 1.02 MPa. CONCLUSION: Within the limitations of the study, amongst all the four groups tested, custom-made resin post luted with self-etch system (CMPR-SE) showed higher micro-push-out bond strength values in all regions when compared to the other groups.
    [Abstract] [Full Text] [Related] [New Search]