These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: A comparison of the diagnostic performance of the ST/HR hysteresis with cardiopulmonary stress testing parameters in detecting exercise-induced myocardial ischemia. Author: Zimarino M, Barnabei L, Madonna R, Palmieri G, Radico F, Tatasciore A, Bellisarii FI, Perrucci GM, Corazzini A, De Caterina R. Journal: Int J Cardiol; 2013 Sep 30; 168(2):1274-9. PubMed ID: 23260751. Abstract: BACKGROUND: Because ST segment depression has limited diagnostic performance at exercise electrocardiography (ECG), ST segment depression/heart rate (ST/HR) hysteresis and cardiopulmonary exercise test (CPET)-derived parameters have been proposed as alternatives to diagnose exercise-induced myocardial ischemia. We compared the diagnostic performance of such parameters. METHODS: We studied 56 subjects (45 men, 11 women, age 59.7 ± 13.6 years) referred for suspected exercise-induced myocardial ischemia with an equivocal ECG exercise test. All subjects serially underwent CPET and a myocardial single-photon emission computerized tomography (SPECT) perfusion imaging (as the gold standard for ischemia). Maximum ST depression at peak exercise (ST-max), the ST/HR hysteresis, ΔVO2/ΔWR b-b1 slope, ΔVO2/ΔWR (aa1-bb1), VO2/HR flattening duration and other CPET parameters were derived in all subjects. RESULTS: On the basis of SPECT, 23 subjects (41%) were considered ischemic and 33 subjects (59%) non-ischemic. ST/HR hysteresis was higher (0.026 mV; 95% CI: 0.003 to 0.049 vs -0.016 mV; 95% CI: -0.031 to -0.001 mV) and ST-max was lower (-0.105 mV; 95% CI: -0.158 to -0.052 vs 0.032 mV; 95% CI: -0.001 to -0.066 mV) in ischemic vs non-ischemic subjects (P=0.004 and P=0.001, respectively). Among CPET parameters, ΔVO2/ΔWR b-b(1) slope was lower (9.4 ± 3.8) and ΔVO2/ΔWR (aa(1)-bb(1)) was higher (2.1 ± 2.6) in ischemic vs non-ischemic subjects (11.4 ± 2.3, P=0.005, and 1.1 ± 1.5, P=0.001, respectively). The ST/HR hysteresis had the highest area under the curve value, better (P<0.05) than any other parameters tested, thus showing the highest overall diagnostic performance. CONCLUSION: The ST/HR hysteresis is superior to CPET-derived parameters for detecting exercise-induced myocardial ischemia in patients with equivocal ECG exercise test results.[Abstract] [Full Text] [Related] [New Search]