These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Accuracy of noninvasive haemoglobin measurement by pulse oximetry depends on the type of infusion fluid. Author: Bergek C, Zdolsek JH, Hahn RG. Journal: Eur J Anaesthesiol; 2013 Feb; 30(2):73-9. PubMed ID: 23303244. Abstract: CONTEXT: Measurement of blood haemoglobin concentration by pulse oximetry could be of value in determining when erythrocytes should be transfused during surgery, but the effect of infusion fluids on the results is unclear. OBJECTIVE: To study the effect of crystalloid and colloid fluid on the accuracy (bias) and precision of pulse oximetry haemoglobin estimation to indicate the venous haemoglobin concentration in volunteers. DESIGN: Open interventional crossover study. SETTING: Single university hospital. PARTICIPANTS: Ten male volunteers aged 18-28 (mean 22) years. INTERVENTIONS: Each volunteer underwent three infusion experiments on separate days and in random order. The infusions were Ringer's acetate (20 ml kg), hydroxyethyl starch 130/0.4 (10 ml kg) and a combination of both. RESULTS: At the end of the infusions of Ringer's acetate, pulse oximetry haemoglobin concentration had decreased more than the true haemoglobin concentration (15 vs. 8%; P < 0.005; n = 10) whereas starch solution decreased pulse oximetry haemoglobin concentration less than true haemoglobin concentration (7 vs. 11%; P < 0.02; n = 20). The same differences were seen when the fluids were infused separately and when they were combined. The overall difference between all 956 pairs of pulse oximetry haemoglobin concentration and true haemoglobin concentrations (the bias) averaged only -0.7 g l whereas the 95% prediction interval was wide, ranging from -24.9 to 23.7 g l. In addition to the choice of infusion fluid, the bias was strongly dependent on the volunteer (each factor, P < 0.001). CONCLUSION: The bias of measuring haemoglobin concentration by pulse oximetry is dependent on whether a crystalloid or a colloid fluid is infused. TRIAL REGISTRATION: ClinicalTrials identifier: NCT01195025.[Abstract] [Full Text] [Related] [New Search]