Search MEDLINE/PubMed
Title: High pressure percutaneous transtracheal ventilation: the use of large gauge intravenous-type catheters in the totally obstructed airway. Author: Stothert JC, Stout MJ, Lewis LM, Keltner RM. Journal: Am J Emerg Med; 1990 May; 8(3):184-9. PubMed ID: 2331256. Abstract: Percutaneous transtracheal ventilation using a large gauge intravenous-type catheter can be used successfully in the setting of complete upper airway obstruction in animals. In this study, using a large animal model, satisfactory oxygenation and ventilation was achieved by inversely varying the catheter size and the inspiration to expiration ratio (I:E). Specifically, 30 to 63 kg ruminants with an obstructed upper airway were resuscitated for 30 minutes from a hypoxic, hypercarbic, and acidotic state using 12- and 14-gauge catheters connected to a 50 psi oxygen source via a two-way valve with an I:E of 1:4 and 1:9 seconds, respectively. Shorter expiratory time or increased inspiratory time with these intravenous catheters resulted in significant hemodynamic compromise, barotrauma, inadequate carbon dioxide elimination, acidemia, and frequent death.[Abstract] [Full Text] [Related] [New Search]