These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Transfemoral access for valve in valve implantation of an Edwards Sapien XT valve in a stenotic tricuspid bioprosthesis under fluoroscopic guidance. Author: Greif M, Schramm R, Steinbeck G, Hagl C, Schmitz C, Kupatt C. Journal: Can J Cardiol; 2013 Aug; 29(8):1014.e3-4. PubMed ID: 23406738. Abstract: A 53-year-old man presented with a high grade stenotic tricuspid bioprosthesis and an inoperable state because of progressive lung disease. Valve replacement was performed transfemorally under local anaesthesia without rapid pacing. Valve positioning was facilitated by the radiopaque frame of the degenerated bioprosthesis. Echocardiography revealed a decrease of peak tricuspid valve gradient from 18 to 8 mm Hg. Valve-in-valve implantation of an Edwards Sapien XT valve in a failing tricuspid bioprosthesis is feasible via transfemoral access without general anaesthesia or rapid pacing.[Abstract] [Full Text] [Related] [New Search]