These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Usefulness of sleep-disordered breathing to predict occurrence of appropriate and inappropriate implantable-cardioverter defibrillator therapy in patients with implantable cardioverter-defibrillator for primary prevention of sudden cardiac death. Author: Kreuz J, Skowasch D, Horlbeck F, Atzinger C, Schrickel JW, Lorenzen H, Nickenig G, Schwab JO. Journal: Am J Cardiol; 2013 May 01; 111(9):1319-23. PubMed ID: 23411108. Abstract: Advanced heart failure (HF) is associated with severe sleep-disordered breathing (SDB). In addition, most patients with HF are treated with an implantable cardioverter-defibrillator (ICD) for primary prevention of sudden cardiac death. The incidence of ICD therapy in such a patient cohort with SDB has never been investigated. The present study sought to determine the effect of SDB on the incidence of appropriate and inappropriate ICD therapy in patients with a categorical primary prevention ICD indication. A total of 133 consecutive ICD patients with New York Heart Association class II-III HF and depressed left ventricular function (≤35%) with no history of ventricular arrhythmia underwent a sleep study before ICD implantation and were followed for 24 ± 8 months, prospectively. A relevant SDB was defined as an apnea-hypopnea index of ≥10 events/hour. Of these 133 patients, 82 (62%) had SDB. Overweight (body mass index >29.1 vs 24.7 kg/m(2); p <0.001) was identified as the only independent risk factor for SDB. Appropriate ICD therapy intervention was significantly greater among patients with SDB than among patients without SDB (54% vs 34%, p = 0.03). Inappropriate ICD therapy intervention was documented more often in patients with SDB (n = 24 [29%] vs 7 [14%]; p = 0.04). An apnea-hypopnea index >10 events/hour was an independent predictor of appropriate ICD therapy on multivariate analysis (odds ratio 2.5, 95% confidence interval 1.8 to 4.04; p = 0.01). In conclusion, the present study is the first trial exploring the effect of SDB on the incidence of appropriate and inappropriate ICD therapy in patients with HF with a primary prevention indication. These results indicate that a preimplantation sleep study will identify patients with HF prone to receive appropriate and inappropriate ICD therapy.[Abstract] [Full Text] [Related] [New Search]