These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Diagnostic accuracy of combined coronary angiography and adenosine stress myocardial perfusion imaging using 320-detector computed tomography: pilot study. Author: Nasis A, Ko BS, Leung MC, Antonis PR, Nandurkar D, Wong DT, Kyi L, Cameron JD, Troupis JM, Meredith IT, Seneviratne SK. Journal: Eur Radiol; 2013 Jul; 23(7):1812-21. PubMed ID: 23430194. Abstract: OBJECTIVES: To determine the diagnostic accuracy of combined 320-detector row computed tomography coronary angiography (CTA) and adenosine stress CT myocardial perfusion imaging (CTP) in detecting perfusion abnormalities caused by obstructive coronary artery disease (CAD). METHODS: Twenty patients with suspected CAD who underwent initial investigation with single-photon-emission computed tomography myocardial perfusion imaging (SPECT-MPI) were recruited and underwent prospectively-gated 320-detector CTA/CTP and invasive angiography. Two blinded cardiologists evaluated invasive angiography images quantitatively (QCA). A blinded nuclear physician analysed SPECT-MPI images for fixed and reversible perfusion defects. Two blinded cardiologists assessed CTA/CTP studies qualitatively. Vessels/territories with both >50 % stenosis on QCA and corresponding perfusion defect on SPECT-MPI were defined as ischaemic and formed the reference standard. RESULTS: All patients completed the CTA/CTP protocol with diagnostic image quality. Of 60 vessels/territories, 17 (28 %) were ischaemic according to QCA/SPECT-MPI criteria. Sensitivity, specificity, PPV, NPV and area under the ROC curve for CTA/CTP was 94 %, 98 %, 94 %, 98 % and 0.96 (P < 0.001) on a per-vessel/territory basis. Mean CTA/CTP radiation dose was 9.2 ± 7.4 mSv compared with 13.2 ± 2.2 mSv for SPECT-MPI (P < 0.001). CONCLUSIONS: Combined 320-detector CTA/CTP is accurate in identifying obstructive CAD causing perfusion abnormalities compared with combined QCA/SPECT-MPI, achieved with lower radiation dose than SPECT-MPI. KEY POINTS: • Advances in CT technology provides comprehensive anatomical and functional cardiac information. • Combined 320-detector CTA/adenosine-stress CTP is feasible with excellent image quality. • Combined CTA/CTP is accurate in identifying myocardial ischaemia compared with QCA/SPECT-MPI. • Combined CTA/CTP results in lower patient radiation exposure than SPECT-MPI. • CTA/CTP may become an established imaging technique for suspected CAD.[Abstract] [Full Text] [Related] [New Search]