These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Determination of aflatoxins B1, B2, G1, and G2 in olive oil, peanut oil, and sesame oil using immunoaffinity column cleanup, postcolumn derivatization, and liquid chromatography/fluorescence detection: collaborative study. Author: Bao L, Liang C, Trucksess MW, Xu Y, Lv N, Wu Z, Jing P, Fry FS. Journal: J AOAC Int; 2012; 95(6):1689-700. PubMed ID: 23451385. Abstract: The accuracy, repeatability, and reproducibility characteristics of a method using immunoaffinity column (IAC) cleanup with postcolumn derivatization and LC with a fluorescence detector (FLD) for determination of aflatoxins (AFs; sum of AFs B1, B2, G1, and G2) in olive oil, peanut oil, and sesame oil have been established in a collaborative study involving 15 laboratories from six countries. Blind duplicate samples of blank, spiked at levels ranging from 0.25 to 20.0 microg/kg for AF, were analyzed. A naturally contaminated peanut oil sample was also included. Test samples were extracted with methanol-water (55 + 45, v/v). After shaking and centrifuging, the lower layer was filtered, diluted with water, and filtered through glass microfiber filter paper. The filtrate was then passed through an IAC, and the toxins were eluted with methanol. The toxins were then subjected to RPLC-FLD analysis after postcolumn derivatization. Average recoveries of AFs from olive oil, peanut oil, and sesame oil ranged from 84 to 92% (at spiking levels ranging from 2.0 to 20.0 microg/kg); of AFB1 from 86 to 93% (at spiking levels ranging from 1.0 to 10.0 microg/kg); of AFB2 from 89 to 95% (at spiking levels ranging from 0.25 to 2.5 microg/kg); of AFG1 from 85 to 97% (at spiking levels ranging from 0.5 to 5.0 microg/kg); and of AFG2 from 76 to 85% (at spiking levels ranging from 0.25 to 2.5 microg/kg). RSDs for within-laboratory repeatability (RSD(r)) ranged from 3.4 to 10.2% for AF, from 3.5 to 10.9% for AFB1, from 3.2 to 9.5% for AFB2, from 6.5 to 14.9% for AFG1, and from 4.8 to 14.2% for AFG2. RSDs for between-laboratory reproducibility (RSDR) ranged from 6.1 to 14.5% for AF, from 7.5 to 15.4% for AFB1, from 7.1 to 14.6% for AFB2, from 10.8 to 18.1% for AFG1, and from 7.6 to 23.7% for AFG2. Horwitz ratio values were < or = 2 for the analytes in the three matrixes.[Abstract] [Full Text] [Related] [New Search]