These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Quantitative solid phase microextraction - gas chromatography mass spectrometry analysis of the pesticides lindane, heptachlor and two heptachlor transformation products in groundwater.
    Author: McManus SL, Coxon CE, Richards KG, Danaher M.
    Journal: J Chromatogr A; 2013 Apr 05; 1284():1-7. PubMed ID: 23466207.
    Abstract:
    This paper describes the development and validation of a method for the determination of lindane, heptachlor and two heptachlor transformation products (exo- and endo-heptachlor epoxide) in groundwater. Samples were extracted using a simple solid phase microextraction (SPME) method with a polyacrylate fibre prior to detection by gas chromatography mass spectrometry in electron impact ionisation mode (GC-EI-MS). The linearity of the method ranged from 0.015 to 5.0 μg L(-1), with correlation coefficients greater than 0.99. Recoveries ranged from 96 to 101% at several fortification levels with all coefficients of variation (CV%) less than 10.5%. The method was validated to the permitted limits laid down in the European Union drinking water directive (98/83/EC). The limit of quantitation (LOQ) was 0.015 μg L(-1) in groundwater samples. Samples had to be analysed within 24h of collection otherwise degradation occurred and disposable SPME polyacrylate fibres lasted up to 51 injections. Both endo-heptachlor epoxide and lindane were detected in groundwater samples with concentrations ranging between 0.033 and 0.048 μg L(-1).
    [Abstract] [Full Text] [Related] [New Search]