These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Experimental and theoretical investigations of some useful langasite cuts for high-temperature SAW applications.
    Author: Bardong J, Aubert T, Naumenko N, Bruckner G, Salzmann S, Reindl LM.
    Journal: IEEE Trans Ultrason Ferroelectr Freq Control; 2013 Apr; 60(4):814-23. PubMed ID: 23549542.
    Abstract:
    Passive high-temperature sensors are a most promising area of use for SAW devices. Langasite (La3Ga5SiO14; LGS) has been identified as promising piezoelectric material to meet high-temperature SAW challenges. Because it is necessary to know the material behavior for an accurate device design, the frequency¿temperature behavior of Rayleigh SAW (R-SAW) and shear-horizontal SAW (SH-SAW) LGS cuts is investigated on delay line and resonator test structures up to 700°C by RF characterization. In the range of the 434-MHz ISM band, the (0°, 22°, 90°) SH-SAW cut shows thermal behavior similar to the (0°, 138.5°, 26.7°) R-SAW cut. Associated with the (0°, 22°, 31°) cut, in which SAWs present mixed types of polarization, the (0°, 22°, 90°) SH-SAW orientation might allow differential measurements on a single substrate. In the temperature range of 400 to 500°C, delay line test devices using the SH-SAW cut show a considerable drop of signal. Theoretical analysis indicates that this newly described behavior might be a result of anisotropy effects in this cut, occurring in case of any slight misorientation of electrode alignment.
    [Abstract] [Full Text] [Related] [New Search]