These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Quantification of superparamagnetic iron oxide using inversion recovery balanced steady-state free precession. Author: Pelot NA, Bowen CV. Journal: Magn Reson Imaging; 2013 Jul; 31(6):953-60. PubMed ID: 23601361. Abstract: Cellular and molecular MRI trafficking studies using superparamagnetic iron oxide (SPIO) have greatly improved non-invasive investigations of disease progression and drug efficacy, but thus far, these studies have largely been restricted to qualitative assessment of hypo- or hyperintense areas near SPIO. In this work, SPIO quantification using inversion recovery balanced steady-state free precession (IR-bSSFP) was demonstrated at 3T by extracting R2 values from a monoexponential model (P. Schmitt et al., 2004). A low flip angle was shown to reduce the apparent recovery rate of the IR-bSSFP time course, thus extending the dynamic range of quantification. However, low flip angle acquisitions preclude the use of traditional methods for combining RF phase-cycled images to reduce banding artifacts arising from off-resonance due to B0 inhomogeneity. To achieve R2 quantification of SPIO, we present a new algorithm applicable to low flip angle IR-bSSFP acquisitions that is specifically designed to identify on-resonance acquisitions. We demonstrate in this work, using both theoretical and empirical methods, that the smallest estimated R2 from multiple RF phase-cycled acquisitions correspond well to the on-resonance time course. Using this novel minimum R2 algorithm, homogeneous R2 maps and linear R2 calibration curves were created up to 100μg(Fe)/mL with 20° flip angles, despite substantial B0 inhomogeneity. In addition, we have shown this technique to be feasible for pre-clinical research: the minimum R2 algorithm was resistant to off-resonance in a single slice mouse R2 map, whereas maximum intensity projection resulted in banding artifacts and overestimated R2 values. With the application of recent advances in accelerated acquisitions, IR-bSSFP has the potential to quantify SPIO in vivo, thus providing important information for oncology, immunology, and regenerative medicine MRI studies.[Abstract] [Full Text] [Related] [New Search]