These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Determination of retinol and α-tocopherol in human seminal plasma using an HPLC with UV detection.
    Author: Kanďár R, Drábková P, Myslíková K, Hampl R.
    Journal: Andrologia; 2014 Jun; 46(5):472-8. PubMed ID: 23611772.
    Abstract:
    Oxidative stress has been proposed as one of the potential causes for infertility in men. Retinol and α-tocopherol have an important role in the spermatozoa defences against oxidative stress. A method is described here for the simultaneous determination of retinol and α-tocopherol in human seminal plasma with a suitable sample preparation procedure to prevent retinol and α-tocopherol degradation. After adequate sample preparation, the samples were determined by reversed-phase column chromatography with UV detection. The analytical performance of this method was satisfactory. The intra-assay and inter-assay coefficients of variation were below 10%. The recoveries were as follows: 90.7% (CV 8.1%) for retinol and 98.2% (CV 4.8%) for α-tocopherol. No significant differences in both retinol and α-tocopherol concentration between the smokers and nonsmokers (15 ± 7 nm and 1.86 ± 0.29 μm versus 15 ± 6 nm and 1.93 ± 0.45 μm) were found. A selective high-performance liquid chromatography method for the determination of retinol and α-tocopherol in human seminal plasma was developed.