These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Lethal post-endoscopic retrograde cholangiopancreatography pancreatitis following fully covered metal stent placement in distal biliary obstruction due to unresectable cholangiocarcinoma. Author: Itoi T, Tsuchiya T, Tanaka R, Ikeuchi N, Sofuni A. Journal: Dig Endosc; 2013 May; 25 Suppl 2():117-21. PubMed ID: 23617661. Abstract: Biliary self-expandable metallic stent (SEMS) is the preferred and first-line therapy for unresectable malignant biliary obstruction. To date, several reports have revealed the relatively high incidence of acute complications such as pancreatitis and cholecystitis due to mechanical stent compression. In the present case, we encountered fatal pancreatitis following fully covered metal stent placement. An 85-year-old man had middle bile duct strictures due to cholangiocarcinoma. A 10-mm diameter fully covered SEMS was placed across the papilla for biliary decompression. Laboratory data and physical evidence the following day revealed acute pancreatitis. Therefore, antibiotics and protein degeneration enzyme inhibitors were given. However, his condition did not improve. Two days after the procedure, we removed the stent and returned him to his original hospital. Serum amylase level decreased below 400 mg/dL 6 h after the procedure. However, the acute pancreatitis worsened. Although we treated the patient in the intensive care unit, he died 32 days after the second admission.[Abstract] [Full Text] [Related] [New Search]