  • Title: [HPLC fingerprint of compound xueshuantong capsule].
    Author: Liang JP, Liu ZZ, Peng W, Su WW.
    Journal: Zhong Yao Cai; 2012 Nov; 35(11):1854-8. PubMed ID: 23627102.
    Abstract:
    OBJECTIVE: To establish the HPLC fingerprint of Compound Xueshuantong Capsule. METHODS: Dionex Acclaim 120 C18 column (4.6 mm x 150 mm, 3 microm) was used with acetonitrile (A) and 0.05% phosphoric acid (B) in gradient elution mode. The elution profile was:0-50 min (15%-->34% A), 50-95 min (34%-->75% A); The detective wavelength was 203 nm and 270 nm. The column temperature was set at 25 degrees C and the flow rate was 1.0 mL/min. RESULTS: In the established fingerprint,42 common peaks covering 4 medicinal materials were detected, and 23 chemical compounds were identified by RRLC/MS/MS and DAD spetra. CONCLUSION: The method can be used for quality control of Compound Xueshuantong Capsule with great precision, accuracy and good reproducibility.